Quick intro: Whether it’s an electric strike or a maglock, these steps can get you back to secure.
• Power: blown fuse, tripped breaker, loose transformer, failed supply
• Schedule/Mode: door held unlocked by a schedule/manual override
• Door position: misaligned latch/strike keeps it from securing
• Controller: door forced/held alarms, offline panel, bad relay
• Mechanical lock issues → locksmith.
• Electronic lock or access-control logic → BBC Systems.
• No power to the maglock
• Fire alarm drop engaged (maglocks must release on fire)
• Stuck REX or motion sensor holding the door in exit mode
• Door not closing flush (gap/debris)
• Held-open schedule in software
The access controller, power supply, REX devices, door position switch, and a fire-alarm relay (drops power during emergencies).
Quick checks (safe)
• Ensure the door fully closes to the magnet (no gap; plate clean)
• Verify the exit sensor/button isn’t stuck active
• After a fire alarm, maglocks may stay released until reset—call us if they don’t re-secure
• Multiple maglocks out → check the power supply (LEDs/fuses)
When it’s definitely a service call
• Anything tied to the fire-alarm interface
• Power-supply faults, blown fuses, wiring damage
• Controller offline or multiple doors impacted